The LS-OD-6 sorter is designated for the pre-final and final re-treatment of dry concentrate with grain size - 5 + 2, - 2 + 1, and -1 + 0.5 mm.
The sorter's operation concept is based on the use of diamonds' property of luminescent under X-ray impact and on the difference of those properties with diamonds and associate luminescent minerals. This is the implementation of the mode conditionally labeled as "luminescent and absorption", when the X-ray tube and luminescent receptors are located on both sides of the material flow. Herein, the effect of difference in X-ray absorption by diamonds and associate luminescent minerals is used.
Special Features and Specifications
| Material to be processed | Dry, thoroughly dedusted, classified (contents of main class 85% minimum) |
| Material grain size classes | - 5 + 2, - 2 + 1 and - 1 + 0.5 mm |
| Material feed and transportation system | Grain-by-grain, 4-stream, one-pass type. Loading hopper (with a flange to connect to the mill's transportation system, option: manual material load) - shaking supply feeder - stretch shaking feeder - outer divider plate (concentrate-tailing) - concentrate and tailing channels (with flanges to connect to the relevant mill's pipelines). |
| Capacity | To 50 kg/hr (- 5 + 2 mm); |
| X-ray: | 1 |
| Detection: | Single-sided material luminescent detection. |
| Ejection | Pneumatic, with compressed air, by means of solenoid-operated pneumatic valves |
| Recovery | Min. 98% (- 5 + 2 mm); |
| Outward flow of material per 10 splitters (at maximum capacity) | Max. 30 grains (- 5 + 2 mm), 45 grains (- 2 + 1 and - 1 + 0.5 mm) |
| Automation Extra option (supplied after a special order): Protection system against unauthorized access to SM, material | Checking of main systems prior to start of material feed and in the course of operation (material feed is stopped if fault is detected) Sensitivity Failure indication. Monitoring and control from the concentration mill's Automated Process Checking System |
| Electric power supply | 380V ± 10%; 50 Hz±2%; 3 kVA |
| Flow rate for potable quality water to cool the tubes | 6 l/min max. |
| Average compressed air flow (0.4 Mpa) with 10 splits/sec | 0.01 m³/min |
| Overall dimensions (LxWxH), mass: | 1350×800×1810 mm, 900 kg; |
| Operation conditions: |
From + 10°С to + 35°С. |
| Relative humidity (at ambient air temperature + 25°С) | To 80% |