The LS-50-05 Sorter is designated for the enrichment of wet basic diamond ore and re-treatment the concentrate with grain size - 50 + 20, - 20 + 10 and - 10+5 mm.
The sorter's operation concept is based on the use of diamonds' property of luminescent under X-ray impact and on the difference of those properties with diamonds and associate luminescent minerals. The following different analysis mode are implemented:
- with single-side placement of the X-ray tube and luminescent receivers relatively to the material flow;
- the mode conditionally labeled as «luminescent and absorption", when the X-ray tube and luminescent receptors are located on both sides of the material flow; herein, the effect of difference in X-ray absorption by diamonds and associate luminescent minerals is used;
The sorter includes a sorting machine (SM) and an automated control rack (ACR).
Special Features and Specifications
| Material to be processed | Wet, clean from mud and sorted materials, classified (contents of main class 85% minimum) |
| Material grain size classes | - 50 + 20; -20 +10 and -10 + 5 mm. |
| Material feed and transportation system | Flow-type, two treatment pass. |
| Capacity | To 30 t/hr (- 50 + 20 mm) |
| X-ray: | One tube per each pass. |
| Detection: | Single-sided material luminescent detection. |
| Ejection | Pneumatic, with compressed air, by means of solenoid-operated pneumatic valves |
| Recovery | 98% minimum |
| Outward flow of material per one splitter (with maximum capacity) | 0.2 kg maximum (- 50 + 20 mm), 0.15 kg (- 20 + 10 mm), 0.05 kg (- 10 + 5 mm) |
| Automation | Checking of main systems prior to start of material feed and in the course of operation (material feed is stopped if fault is detected) Sensitivity Failure indication. Monitoring and control from the concentration mill's Automated Process Checking System |
| Electric power supply | 380V ± 10%; 50 Hz±2%; 6 kVA |
| Flow rate for transportation water (0.015 MPa) | 1.8 ( m³/hr) max. |
| Flow rate for potable quality water to cool the tubes | 6 l/min max. |
| Flow rate for potable quality water to wash the windows of photo detectors and tube collimators (0.3 MPa) | 0.4 l/min max. |
| Average compressed air flow rate (0.4 MPa) | 0.015 m³/min |
| Overall dimensions (LxWxH), mass: |
2550×870×2580 mm; 1600 kg |
| Operation conditions: |
From + 10°С to + 35°С. |
| Relative humidity (at ambient air temperature + 25°С) | SM - to 100% ACR - to 80% |